EnglishFrenchGermanItalianPortugueseRussianSpanish

The compressed air of the air compressor is not completely dewatered. What is the reason?

1. The filter element of oil-water separator may have failed
2. The adsorption material used in the adsorption dryer is not tightly filled
3. Due to the large change of air humidity, the timing drainage adjustment is not timely, so that too much ponding in the filter is brought into the compressed air
4. The cooler of the air compressor is blocked by dust, which makes it more difficult to remove water from the post-treatment equipment
5. The air consumption of the air compressor is large, which exceeds the range of the air compressor