EnglishFrenchGermanItalianPortugueseRussianSpanish

How to deal with air compressor not pumping automatically?


Air compresso
r does not pump the cause of failure
1.air compressor loose pressure valve stagnation. Valve piece deformation or fracture.
2.There is too much carbon in the inlet and exhaust port
3.Failure of three-way solenoid valve
4.Discharge solenoid valve failure
5.Control line leakage

Air compressor does not hit the air exclusion method
1.Check the loose pressure valve component, clean and replace the failed parts
2.Disassemble and check the cylinder head, check the valve piece, replace the deformed and broken valve piece
3.Check and replace the three-way solenoid valve
4.check and replace the drain solenoid valve
5.Check the leak location after processing